Products

Sandwich Panel

Panel Tech’s specialized in production, sales and export of Polyurethane (PU) & Polyisocyanurate (PIR) Insulated Sandwich Panel & Rockwool. Sandwich Panels are produced in a continue line with 3 types of insulation materials including such as, Polyurethane (PUR), Polyisocyanurate (PIR) & Rockwool insulation thicknesses. As external and internal surfaces of sandwich panel painted galvanized, galvalume, Alu-zinc, stainless steel, Painted or natural aluminum materials can be used.

They are manufactured as polyester, plastisol, PVDF and food safe painted according to the needs of the Project. They can bemanufactured in all RAL codes. Panel Tech’s Insulated Roof and Wall Sandwich Panels are responding all needs such as thermal insulation, air tightness, hygiene, aesthetics, fire insulation. Acoustic insulated Roof and Wall Panels for sound insulationWall Panel for container and prefabricated buildings and Cold Room Panels for cold storages.

Some of the benefits of using Panel Tech’s sandwich panels are:

Roof Sandwich Panel

Roof panel with PIR (polyisocyanurate) and PU (polyurethane core). High surface profile.
Application:
Suitable for roofs of industrial buildings: production halls, storage buildings, commercial halls, shopping centres, farm facilities. Steel sheet lining with anticorrosive protection depending on the intended use.

Wall Sandwich Panel

Roof panel with PIR (polyisocyanurate) and PU (polyurethane core). High surface profile.
Application:
Suitable for roofs of industrial buildings: production halls, storage buildings, commercial halls, shopping centres, farm facilities. Steel sheet lining with anticorrosive protection depending on the intended use.

Low Ribbed Wall Sandwich panel with PIR (polyisocyanurate)and PU (polyurethane core).
Application:
Suitable for building external and internal walls of industrial buildings: production halls, storage buildings, commercial halls, shopping centres, farm facilities. Vertical or horizontal installation. Steel sheet lining with anticorrosive protection depending on the intended use.

Corrugated Profile Sheets

Profiled steel or Aluminium sheets are used in various roof constructions. Profile Sheets can be produced from galvanized sheet metal or Aluminium, as coil coating painted, in various thicknesses and forms. They are used as single layer without thermal insulation or, as multi-layer roof and wall applications where thermal insulation is laid down in between two corrugated sheets.

We offer our customers with Steel Roofing Solutions that are highly result oriented and quality focused. Our team of experts work closely with customers to understand their necessity and offer the services accordingly. We ensure all the services are offered within a stipulated time frame to ensure they accomplish the need of customers. Our complete range of services can be availed by our customers at market leading price.

We bring forth the finest range of Color Profile Sheets for our valued clients. Developed with advent technology, these color profile sheets are suitable to cover different warehouses, sheds and temporary houses. We offer these color profile sheets in different sizes and colors.

Applications

Metal Decking Sheet

Multideck Floor System High performance, profiled, galvanized steel floor decking for use in the construction of composite floor slabs. The profile may also be used as a permanent shuttering.

Metal deck is a structural panel element that acts as the surface of a floor or roof. The deck is roll formed from structural quality sheet steel and is engineered to span over joist or purlins. Variations in the thickness, shape and depth of the deck can be utilized to meet a variety of loading conditions and spans. The deck can also be fastened to the supporting structure to enable it act as a diaphragm and provide lateral bracing for the structure.

Metal deck flooring is typically used for multi-story buildings, mezzanines, bridge walkways, porches, in-fills, platforms and parking garages, storage facilities etc.

Applications

Z & C Purlins

Panel Tech manufactures a complete range of structural C and Z purlins and girts for industrial buildings, garages, verandahs, and carports, in fact anywhere that strong reliable steel framing is required. Manufactured from quality galvanized steel, this is a fully integrated system allowing for flexible design options.

Supplied plain or punched, galvanized purlins are manufactured from high tensile steel for increased strength, reduced weight, and a long serviceable life. Panel Tech offers the fastest service in town. Installation of new state of the art machinery allows not only faster production times, but greater flexibility to meet your needs. A guide to standard lead times can be seen in the table below: For larger projects, some additional time may be required. Panel Tech’s purlins are crisp, clean and square and by any assessment are a quality product. There is need to tolerate rounded corners, inaccurate lengths,

Applications

Specification

Z-section Dimensions and Properties

The section reference of a Z-section 232mm deep and 1.8mm thick would be 232 Z 18. The first 3 digits of the section reference indicate the depth of the section in millimeters (i.e. 232 equals 232mm deep). The fourth digit is a letter that signifies the profile type (ie Z for Z-section). The last two digits indicate the material thickness (i.e. 18 =1.8mm).

Translucent Sheet

To let natural daylight into a sheeted building you can replace some of the metal sheet panels with Translucent Sheet, clear sheets made match PTI Profiles 32/250. Our clear roof sheets are made from high grade GRP glass fiber and Polycarbonate of 1.5mm thickness, offering extremely high impact resistance, minimizing the risk of breakage. They let in diffused daylight at a transmission rate of over 80% and give excellent flexibility and light stability, featuring a protective polyester film bonded to both surfaces preventing moss and lichen growth and discoloration as well as protection against the degrading effects of ultra-violet radiation in natural sunlight.

Applications:

Translucent sheets are used where moderate corrosion protection and weathering characteristics are required. This panel can be used in such application as refineries, pulp and paper mills, mining operations, wastewater facilities, fertilizers plants Roofing, warehouse, car Shed, swimming pools, gardens, walkways and cladding for structures, industrial facilities public building etc.

Double Layered GRP Translucent Sheet

GRP Double Layered Translucent sheets are manufactured by using U.V stabilized clear thermosetting polyester resins of translucent grade. These sheets allow an evenly distributed daylight to pass into factory sheds, warehouses, commercial buildings etc. with good thermal insulation, are nonabsorbent of hydrocarbons and are suitable for the climatic conditions of high temperature in both double and single skin forms. Double layered sheets have comparatively better insulation properties and are normally used with Sandwich Panels.

Physical Properties

Thickness1.5mm ±10% 
Tensile Strength80.3 MpaASTM D63
Flexural Strength120.0 MpaASTM D790
Barcol Hardness48-60ASTM D2583
Density1.43 g/cm³ASTM D792
Water Absorption≤0.25%ASTM D570
Thermal Conductivity0.2 W/mkASTM C518
Light Transmission80% ±5% 
Solar Hear Gain Coefficient0.72 
Fiber Content20% ±10% 

Single Skin Polycarbonate Translucent Sheet

Polycarbonate Translucent is an excellent combination of high strength durability and tough weatherability, which is required by the harsh weather conditions common in the Middle East. Polycarbonate Skylights are the best option for replacement of skylights and new skylight installations.

Our Polycarbonate Translucent are also suitable for Warehouse, Car Shed, Swimming Pools, Gardens, walkways. We keep stock lengths from 3.0 meter to 3.3meter lengths.

Physical Properties

Density1.20 g/cm³ASTM D792
Water Absorption0.15%ASTM D570
Refractive Index1.49ASTM D542
Light Transmission88%ASTM D1003
Rockwell Hardness82 ShoreASTM D785
Izod Impact88 kg-cm/cnASTM D256
Tensile Strength620 Kg/cm²ASTM D638
Tensile Modulus2400 MpaASTM D638
Flexural Strength850-950 Kg/cm²ASTM D790
Flexural Modulus2400 MpaASTM D790
Elongation at Break110%ASTM D638
Co-efficient Thermal expansioncm/cn -˚CASTM D696
Heat Deflection temp @ 264psi125 ˚CASTM D648
Vicat Softening point149 ˚CASTM D1525

Translucent Sheet

Panel Tech can fold a wide range of standard or custom flashings to suit your requirements. Flashings are available in pre-painted steel, zinc/al, aluminum, mill finished galvanized. Choose from a wide range of available thicknesses from 0.3mm to 2.0mm depending on your state.

Box Gutters

A square or rectangular gutter that is used within the boundaries of the roof. It may be formed between a roof surface and a parapet wall or between two roof surfaces. Available with enfold, out fold, splash back and squash fold edges. This gutter is usually supported on a box gutter board to improve strength and stiffness and to minimize damage caused by roof traffic.

Industrial Eave Gutters

A purpose made external gutter which is located at the edge of an industrial roof. It is usually supported by heavy gauge brackets that have been designed specifically to suit the industrial eaves gutter shape. When made in larger sizes special attention should be given to minimizing oil canning of flat surfaces by adding extra ribs into the design.

Valley Gutters

A shallow gutter formed to suit the angle between two internal slopes of a roof. Its design will usually include a return at each edge to minimize the possibility of water spillage into the roof space. Depending on the size and application additional internal stiffening ribs may be included.

Corner Flashings

A folded piece of steel used for waterproofing wall sheeting where two walls meet to form an external corner. Where used with steel sheet walling it should lap at least one rib and a recommended two ribs for maximum water proofing.

Apron Flashings

A folded piece of steel used to prevent water from penetrating the space where a vertical surface intersects a roof. Where used with steel sheet roofing it should lap at least one rib and a recommended two ribs for maximum water proofing. Wider apron flashings are advised when the base of the flashing faces into the prevailing wind.

Ridge Flashings

A steel covering over the ridge to provide a continuous cover and effective weather seal between two slopes. The size of the edge break should conform with the rib height of the steel roofing to which the ridge is attached. Good roofing practice is to notch this edge break to neatly fit around each rib of the roof sheet.

Parapet Capping

A covering used to waterproof and cap the ends of vertical sheets or masonry walls. A stiffening edge or break is often applied to the legs of the parapet cap for a more appealing appearance, and to minimize oil canning of the steel. Ensure that these recommendations are considered when measuring the flashing. It is also important to ensure that water does not pool on top of the cap, to prevent water seeping into the building.

Barge Capping

A folded sheet used to waterproof the junction between a fascia or barge board and roof sheeting. The size of the edge break should conform with the rib height of the steel roofing to which the ridge is attached.

Roller Shutter Doors

The shutter curtain is constructed from cold rolled galvanized concave steel laths, (75mm), of suitable gauge to suit the application. Each lath is retained pressed steel iron end lock fixed with galvanized steel rivets. Cast Iron wind locks are fitted to help prevent the curtain being orced out of the guide during high winds, as and when required.

Heavier duty Roller Shutter Doors are widely used in the building industry Less noise, ease of operation, no grease required. Manufactured from 75mm x 0.5mm/1mm & 1.5mm galvanized slat material Can be manufactured up to 4000 mm (4 meters) Available in a range of standard colors / powder coated.

CURTAIN: Constructed from roll formed galvanized steel interlocking slats with effective width of 100mm. 0.5 steel thickness available dependent on door size and location.

BOTTOM RAIL: Bottom rail is 40mm x 40mm MS angle bolted to bottom slat on curtain. On wider doors 2 angles welded back to back to provide extra strength.

SIDE GUIDES: Galvanized roll formed steel channel with a minimum depth of 50mm and fitted with formed top entry bell mouth. Option as 75 –100mm deep tracks.

DRUMS: Are fabricated from mild steel tube with a minimum diameter of 150mm with a wall thickness sufficient to minimize deflection. Helically wound counter balance springs are contained within the drum.

BRACKETS: Shall be fabricated from at least 8mm mild steel plate and angle. Plates slotted to accommodate shaft and chain or motor mounting. Plates and angles zinc plated finish.

OPERATION: Shall be either manual geared chain hoist or electrically operated. Motorized doors are supplied with 3 phase motor with enclosed gearbox, limit switches, emergency hand chain and push button reversing starter. Single phase motors optional.

FINISH: Standard finish is for galvanized door curtain and guides. All other components metal primed

Accessories

SELF TAPPING SCREW

SELF DRILLING SCREW

PVC SCREW CAP

REINFORCED FOIL TAPE

BUTYL TAPE

RIVETS

PROFILE RIDGE

RUBBER FOAM FILLER

TURBINE ROOF VENT

SEALANT

Scroll to Top